Fabrication of Gelatin-Based Phantom for Evaluating Computed Tomography (CT) Image Noise

Show simple item record

dc.contributor.author Jenna Rose G. Abenes
dc.contributor.author Janella Faye B. Camarillo
dc.contributor.author Adrielle Grace C. Magpali
dc.contributor.author Raenell-An G. Mariano
dc.contributor.author Hazel Say G. Octaviano
dc.contributor.author Ruth Ann O. Sanson
dc.date.accessioned 2026-06-19T08:20:14Z
dc.date.available 2026-06-19T08:20:14Z
dc.date.issued 2026-05-26
dc.identifier.issn 2094-4160
dc.identifier.uri https://research.lorma.edu/xmlui/handle/123456789/299
dc.description.abstract This study aimed to fabricate a gelatin-based phantom and evaluate its effectiveness in assessing CT image noise compared with a commercially available phantom. A quantitative true experimental design was utilized, employing bovine gelatin and sucrose to create a tissue-equivalent phantom. The fabricated phantom was examined using regulated CT parameters, and image quality metrics including mean Hounsfield Unit (HU), standard deviation, signal-to-noise ratio (SNR), and noise power spectrum (NPS) were evaluated. The results indicated that the fabricated phantom yielded consistent HU values and stable noise measurements, confirming its efficacy for dependable CT image assessment. In comparison to the commercial phantom, the fabricated phantom demonstrated marginally reduced image noise and revealed statistically significant differences (p < 0.05), suggesting disparities in material composition and imaging response. Despite these differences, the gelatin-based phantom proved to be as a realistic and economical substitute for CT quality assurance, especially in resource-constrained environments. The results indicate that locally constructed phantoms can facilitate imaging instruction, research, and initial quality control, while providing accessibility and flexibility for future enhancement. en_US
dc.language.iso en_US en_US
dc.publisher Lorma Colleges
dc.subject Image noise en_US
dc.subject gelatin-based phantom en_US
dc.subject diagnostic performance en_US
dc.subject quality assurance en_US
dc.subject computed tomography en_US
dc.subject signal-to-noise ratio en_US
dc.subject noise power spectrum en_US
dc.title Fabrication of Gelatin-Based Phantom for Evaluating Computed Tomography (CT) Image Noise en_US
dc.type Article en_US